MENU
About us
Equipment
OFFERS
Price
Contact
Articles
/
/
VOLNEWMER Monopolar RF Lifting
back
Volnewmer treatment at MED YU MED Dubai

VOLNEWMER Monopolar RF Lifting

Volnewmer is a non-invasive monopolar radiofrequency treatment for skin tightening, firming and facial or body contour support. It suits mild to moderate skin laxity when a patient wants visible firming without incisions.

The device delivers controlled monopolar RF heating into the skin layers, which may support collagen renewal and help improve the appearance of laxity, texture and firmness. The doctor sets the number of pulses by treatment area, tissue condition and skin thickness.

The treatment can be performed on the face, eye area and selected body zones. The doctor or specialist selects the number of pulses according to the treatment area, tissue condition, skin thickness and desired tightening effect. For larger areas, Volnewmer can also be combined with Ultraformer MPT in VOLFORMER protocols, where monopolar RF lifting is paired with HIFU SMAS lifting.

Volnewmer RF lifting prices at MED YU MED start from 1 250 AED for 100 pulses, with customised protocols available up to 1 200 pulses. The final cost depends on the treatment area, number of pulses, skin condition and whether the procedure is performed as a standalone Volnewmer treatment or as a VOLFORMER package with Ultraformer MPT.

  • Skin laxity and loss of firmness on the face and neck
  • A softer jawline and early sagging
  • Crepey, loose skin texture
  • Fine lines linked to lost firmness
  • Patients who want tightening without needles or injectables
  • Suitable across a range of skin tones, with no needles

Pacemakers, metal implants or pregnancy may rule out treatment — confirmed at consultation.

- Pregnancy and breastfeeding
- Age under 18
- Implanted electronic devices anywhere in the body, including pacemakers and defibrillators — not only in the treatment area
- Metal implants, permanent fillers or facial implants in the treatment area, unless approved by the doctor
- Active infection, inflammation, open wounds or herpes in the treatment area
- Active cancer or ongoing cancer treatment
- Uncontrolled chronic, endocrine or autoimmune conditions
- Severe uncontrolled diabetes or impaired wound healing
- Keloid tendency or abnormal scarring risk

This list is not exhaustive. Other conditions, medicines and previous treatments may also rule the treatment out or change the plan. Final suitability is determined by a clinician at an in-person assessment.

- Full face
- Eye area
- Lower face
- Jawline
- Double chin
- Neck, after doctor assessment
- Abdomen
- Knees
- Thighs
- Buttocks
- Body areas with mild to moderate skin laxity
- Areas with scars, stretch marks or striae, after doctor assessment

The procedure is performed on the VOLNEWMER device
Read more about equipment

Before and after

Photos from our practice. Results differ from person to person, and the doctor confirms the number of sessions at your consultation.

Book a procedure appointment VOLNEWMER Monopolar RF Lifting
The highest level of service allows each of our patients to feel comfortable during their visit. Create your own pleasure — choose one of our services

VOLNEWMER Monopolar RF Lifting in Dubai: what the treatment does

VOLNEWMER in Dubai tightens skin with deep heat and no needles. At MED YU MED the treatment runs on the VOLNEWMER system, a monopolar radiofrequency device that works at a high 6.78 MHz frequency. The energy drives heat deep and evenly into the dermis from a handpiece moved across the surface — no punctures and no entry points. That controlled heating contracts existing collagen for an immediate firming effect and sets off new collagen that keeps building for weeks.

Cooling and energy control at the tip protect the surface, so the treatment feels like a warm massage rather than a sharp burn. VOLNEWMER suits the face and neck and works well for patients who want firmer skin but prefer to avoid microneedling or injectables. A DHA-licensed medical team sets the energy and plan at consultation. Results differ between individuals, and the plan is confirmed before the first session.

How VOLNEWMER Monopolar RF Lifting works

VOLNEWMER is monopolar radiofrequency, which means the energy passes from a single handpiece deep into the tissue and returns through a grounding pad, reaching further than the shallower bipolar RF used in many microneedling devices. Running at 6.78 MHz, it heats the dermis quickly and evenly. That deep, controlled heat does two things: it contracts the collagen already in the skin for a firming effect you can often see early, and it injures the tissue just enough to trigger fresh collagen over the weeks that follow.

The treatment is needle-free — the handpiece glides across the surface while cooling and tip control keep the outer skin protected, so the warmth stays comfortable. That makes VOLNEWMER a fit for patients who want tightening on the face and neck without punctures, injections or recovery time. The full device specification sits on the VOLNEWMER device page.

How a session goes: VOLNEWMER Monopolar RF Lifting

  1. Consultation

    Assessment of laxity and skin quality, plus medical history including any implants or pacemaker. The energy and area are planned to your goal.

  2. Preparation

    The skin is cleansed and a conductive medium is applied, and a grounding pad is placed for the monopolar circuit. Settings are matched to the area.

  3. Treatment

    The handpiece is moved across the face or neck as deep, even warmth builds; surface cooling keeps the sensation comfortable, like a warm massage.

  4. Aftercare

    No recovery is needed. SPF is advised, and any short series of sessions is spaced to let collagen build between visits.

Results after VOLNEWMER Monopolar RF Lifting

Some firming often shows soon after a session as existing collagen contracts, but the main result builds over the following weeks as new collagen forms. Many patients have a short series of sessions for the fullest effect, with the clinician setting the number and spacing to your skin and goal. Radiofrequency tightening relaxes gradually over time, so maintenance keeps the result. VOLNEWMER works on its own or alongside other treatments. Results vary between individuals.

Recovery and aftercare after VOLNEWMER Monopolar RF Lifting

Downtime is minimal rather than absent. Warmth can leave a faint flush for a short while; it settles, and normal activity resumes immediately. No needles means no marks and no wound care. Use daily SPF, and keep your usual skincare gentle for the rest of the day while the skin settles.

Risks and side effects. Monopolar radiofrequency heats tissue through the skin, so the risks are thermal. Expected: flushing and warmth for a short while, occasionally mild swelling or tenderness. Less common but important: burns and blistering, prolonged redness, pigment change, and loss of fat in the treated area, which shows as hollowing rather than lifting. The treatment is not compatible with an implanted electronic device such as a pacemaker or defibrillator anywhere in the body, not only in the treatment area, and metal implants, permanent fillers, threads or facial implants in the area change the plan — declare them. Volnewmer does not replace a surgical lift, and the effect is long-lasting rather than permanent.

When to contact us urgently. Call MED YU MED on +971 52 184 5011 (daily 10:00–22:00) if you develop a blister or an open area of skin, a burn, pain that increases rather than eases after the first day, redness and heat spreading beyond the treated area, discharge or fever, or a dark or white patch of skin that was not there before. Eye pain or any change in vision after a treatment near the eyes needs assessment the same day. When the clinic is closed, go to the nearest emergency department or call 998 for an ambulance instead of waiting for us to reopen.

VOLNEWMER Monopolar RF Lifting price in Dubai

VOLNEWMER (monopolar RF-lifting)
ProtocolPrice
1 pulse (price per pulse)17 AED
Eyes (200 pulses)2100 AED · course x3: 5985 AED
Face/body 100 pulses1250 AED · course x3: 3563 AED
Face/body 300 pulses (60 min)3500 AED · course x3: 9975 AED
Face/body 400 pulses (60 min)4500 AED · course x3: 12825 AED
Face/body 500 pulses (60 min)5600 AED · course x3: 15960 AED
Face/body 600 pulses (90 min)6000 AED · course x3: 17100 AED
Face/body 700 pulses (90 min)6500 AED · course x3: 18525 AED
Face/body 800 pulses (90 min)7000 AED · course x3: 19950 AED
Face/body 1000 pulses (90 min)7500 AED · course x3: 21375 AED
Face/body 1200 pulses (90 min)8000 AED · course x3: 22800 AED
VOLFORMER (VOLNEWMER + Ultraformer MPT)
ProtocolPrice
VOLFORMER LIGHT: VOLNEWMER 300 lines + Ultraformer MPT 300 lines4900 AED · course x3: 13965 AED
VOLFORMER MEDIUM: VOLNEWMER 300 lines + Ultraformer MPT 400 lines5400 AED · course x3: 15390 AED
VOLFORMER MAX: VOLNEWMER 300 lines + Ultraformer MPT 500 lines6300 AED · course x3: 17955 AED

Final protocol and cost are set after consultation and depend on the treatment area, the number of sessions and the plan agreed with your doctor. See the full price list.

VOLNEWMER Monopolar RF Lifting: frequently asked questions

How much does VOLNEWMER cost in Dubai?

At MED YU MED VOLNEWMER monopolar RF starts from 1250 AED per session. Course packages are priced per plan, since the number of sessions depends on your skin and goal. An exact quote comes from the consultation.

How is VOLNEWMER different from RF microneedling?

VOLNEWMER is needle-free. Its monopolar radiofrequency heats the dermis from a handpiece moved across the surface, with no punctures. RF microneedling instead delivers energy through fine needles. VOLNEWMER suits patients who want tightening without needles, injections or the short recovery microneedling involves.

How many VOLNEWMER sessions will I need?

Many patients have a short series of sessions for the fullest effect, with the clinician setting the number and spacing at assessment. Some firming shows early, while the main result builds over the following weeks. Maintenance holds it. Results vary between individuals.

Is VOLNEWMER painful?

Most patients describe a comfortable, building warmth, like a warm massage, thanks to surface cooling and energy control at the tip. There are no needles. Say so if any spot feels too hot, and the clinician drops the energy.

Is there any downtime after VOLNEWMER?

None. A light flush can linger briefly, then fades, and you go straight back to your day. There are no needle marks and no wound care. Use daily SPF afterwards.

How long do VOLNEWMER results last?

Radiofrequency builds new collagen, but that collagen relaxes gradually over time, so results are long-lasting rather than permanent. Many patients keep the effect with occasional maintenance sessions. Ageing continues, so ongoing skincare and sun protection help. Results vary between individuals.

What are the risks of monopolar RF lifting?

Flushing and warmth are expected and settle quickly. Less common but real: burns and blistering, prolonged redness, pigment change, and loss of fat in the treated area, which reads as hollowing rather than lifting. An implanted pacemaker or defibrillator anywhere in the body rules the treatment out, and metal implants, permanent fillers, threads or facial implants in the area must be declared because they change how the energy behaves.

Medically reviewed by

Dr. Ilias Dautov

Dr. Ilias Dautov

Aesthetic Medicine Doctor & Dermatologist

DHA License No. 09620692-002

Last reviewed July 2026

The information on this page does not replace a medical consultation. Results are individual. Indications and contraindications are determined by a specialist at an in-person appointment.

Service
Doctors
About us
Equipment
SOON
Price
Contact
Articles

Book a procedure appointment VOLNEWMER Monopolar RF Lifting

Leave your contact details and we will get in touch with you within 5 minutes to confirm the details of your appointment
By submitting a request, you agree to the personal data processing policy.